Microwave Leakage Detector Kit

The Martindale TEK500 is a PASS/FAIL microwave leakage detector for testing both commercial and domestic microwave ovens. The unit is designed to comply with harmonised European standards on permitted exposure levels and it will indicate leakage levels by a simple to use traffic light system which illuminates bright LEDs.


For order quantity more than 50, please feel free to request wholesale quotation

  • Description
  • Specification
  • Key features
  • Technical data

Description

There is a self-test feature which simulates a real microwave input, in order to ensure the unit is working correctly at all times. The leakage tester will indicate at 1, 5 and 10mW/cm2, in accordance with BS EN5175.

The full test procedure for microwave ovens also includes checking that the microwave is heating correctly. The TEK500 includes a second beaker and digital thermometer with simple instructions for checking power output to achieve full compliance with the requirements.

The microwave leakage detector kit is supplied with the leakage detector, two beakers, digital thermometer, carry case, instruction manual and battery. The manual includes the calculations to apply when measuring the microwave output.

 

Specification

Specifications

Frequency of operation 2450MHz ± 25MHz
Threshold Accuracy ±1dB for planewave of all polarisations
Cardinal points >1mW/cm2, >5mW/cm2, >10mW/cm2
Response to step input 2-3 seconds to reach 90% of steady state indication
Overload capacity 50mW/cm2
Indicators LED (green) – battery OK

 

LED (yellow) – 1mW/cm2 – acceptable microwave leakage below safety limit

LEDs (red) at 5 & 10mW/cm2 and audible tone – hazardous microwave leakage above safety limit

Cone spacer prescribed test distance of 50mm is achieved when cone tip is in contact with appliance
Operating temperature -5°C to 40°C
Complies with BS EN 60335-2-25:2002

 

BS EN 60335-2-90:2002

Supply 9V alkaline battery, MN1604 or equivalent
Dimensions 145 x 64 x 30mm

Key features

  • Simple pass / fail leakage detection
  • Complies with latest standards
  • Self test feature
  • Power output testing accessories
  • Two beakers, thermometer and carry case included

 

Technical data

Technical data

Datasheet [Click Here To Donwload