Martindale EPAT2100

Martindale Electric

Dual Voltage Manual PAT Tester with Flash Test

Tests 110V & 240V appliances


For order quantity more than 50, please feel free to request wholesale quotation

  • Description
  • Key features
  • Specification
  • Technical data

Description

The simple one button, one test interface for testing both 240V and 110V appliances speeds up testing. It performs the mandatory tests for earth bond and insulation and has the added benefits of run current, run leakage and flash test making it ideal for both routine onsite testing, tool hire checks and workshop service and repair applications. The EPAT2100 is capable of full high current bond testing at 25A and 8A or can be set to 200mA for safe testing of sensitive IT equipment.

It can be powered by a 110V or 240V supply which enables the run current or run leakage test to be performed without the need for connection to an external power source. The TL150 110V adaptor is included to enable connection to a 110V supply.

The EPAT2100 EasyPAT has a built in lead tester for testing IEC power leads and includes all accessories for fast testing of mains extension leads. The lead tester will perform a polarity test and clearly indicates any faults found during the test.

• Suitable for onsite PAT testing and workshop applications
• Simple one button, one test operation
• Fast and easy Class I & Class II appliance testing
• Tests both 240V and 110V appliances based on supply voltage
• High and low current earth bond tests at 8A, 25A and 200mA
• Insulation test at 500V
• Extension & IEC lead testing built-in
• Run current & leakage tests for full appliance testing
• Hipot / Flash testing for tool hire and workshop service & repair applications
• Mains powered 110V/240V with instant on
• Hard case with storage and removable top

Key features

  • Tests 110V & 240V appliances
  • Class I, Class II & Lead Test
  • High & low current earth bond tests at 8A, 25A, and 200mA IT safe
  • 500V Insulation Test
  • Run current & leakage test
  • Hipot / Flash test for tool hire and workshop service & repair testing
  • Mains powered 110V/240V

Specification

Insulation test Test voltage: 500V DC -0% +20% at 0.5MΩ

 

Short circuit current: 1.5mA DC nominal

Display range: 0-19.9MΩ

Accuracy of indication: ± 5% of rdg ± 1 dgt

Earth continuity 200mA, 8A & 25A
Run current test Range: 0-19.9A

 

Accuracy: ± 10% of rdg ± 1 dgt

Earth leakage test Range: 0-19.9mA

 

Accuracy: ± 10% of rdg ± 1 dgt

Flash test Test voltage: 1.5kV AC – Class I, 3.0kV AC – Class II

 

Display range: 0-19.9mA AC

Usable range: 0-3.5mA AC (current trip @ 4mA nominal)

Accuracy: ± 5% of rdg ± 1 dgt

Leads Earth continuity: 1.5m long
Sockets Mains: 240V 13A to BS 1363, 110V 16A to BS 4343

 

Flash: 4mm high safety socket

Lead test IEC 320
Indicators Flash: neon lamp for active test.

 

Over temperature: red LED

Lead Polarity: Lamp 1 / Lamp 2 red LEDs

Supply Voltage: 110V/240V ±10% 50/60Hz

 

Power consumption: 10/220VA

Complies with LVD: BS EN 61010-1
Weight 5.1kg approx
Dimensions 330 x 263 x 144mm
Includes TL66 bond lead, TL166 flash probe, TL150 110V adaptor, EX332 230V plug to socket leads adaptor, carry case and manual

Technical data

Technical data

Datasheet [Click Here To Download