enquiry list

FREE DELIVERY FOR ORDERS ABOVE $300.00

Extech PQ3350-3

Extech Instruments

3-Phase Power & Harmonics Analyzer

Complete with 3000A 24" flexible current clamp probes


For order quantity more than 50, please feel free to request wholesale quotation

  • Description
  • Key features
  • Specification
  • Technical data

Description

Complete with 3000A 18" flexible current clamp probes. Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings). Flexible clamp probes can be used for wrapping around bus bars and wire bundles. Large backlighting LCD displays up to 35 parameters in one screen. Clamp-on True RMS power measurements with on-screen Harmonics display. Simultaneous display of Harmonics and Waveform. Display of Waveform with Peak Values (1024 samples/period). Analysis of Total Harmonic Distortion (THD-F). Maximum Demand (MDkW, MW, kVA, MVA) with programmable period. Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000). Graphic Phase diagram with 3-Phase system parameters. 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%). Calculated Unbalanced Current through Neutral Line (In). Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%). Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics. Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case.

Key features

  • Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings)
  • Flexible clamp probes can be used for wrapping around bus bars and wire bundles
  • Large backlighting LCD displays up to 35 parameters in one screen
  • Clamp-on True RMS power measurements with on-screen Harmonics display
  • Simultaneous display of Harmonics and Waveform
  • Display of Waveform with Peak Values (1024 samples/period)
  • Analysis of Total Harmonic Distortion (THD-F)
  • Maximum Demand (MDkW, MW, kVA, MVA) with programmable period
  • Adjustable CT ratio (1 to 3000) and VT ratio (1 to 600)
  • Graphic Phase diagram with 3-Phase system parameters
  • 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%)
  • Calculated Unbalanced Current through Neutral Line (In)
  • Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%)
  • Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics
  • Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case

Specification

Specifications Range Basic Accuracy
ACV (True rms) 600V ±(0.5%rdg+5d)
AC Current Model PQ3350-1 (1200A) ±(0.5%rdg+5d)
  Model PQ3350-3 (3000A) ±(0.5%rdg+5d)
Active Power (kW) 9.999MW ±(1%rdg+8d)
Apparent Power (kVA) 9999kVA VA=Vrms x Arms
Reactive Power (kVAR) 9999kVAR VAR= sqr (VA2 -W2 )
Power Factor 0.0 to +1.00 ±(1.5%°rdg±8d)
Frequency 45-65Hz 0.1Hz
Phase -180.0°~ 0°~ +180.0° ±1°
Harmonics 1 to 99 ±2%
Crest Factor 1.00 to 99.99 ±(5%+30d)
Peak AC Voltage accuracy _ ±(5%rdg+30d)
Peak AC Current accuracy _ ±(5%rdg+30d)
Active Power Energy (kWh) 0mWh to 999,999kWh
Reactive Power Energy (kVARh) 0.0kVARh to 1000MWh
Datalogging 52428 records (single phase)/17476 records (3 phase)
Dimensions/Weight 10.1 x 6.1 x 2.3" (257 x 155 x 57mm)/ 2.5 lbs (1160g)

Technical data

Technical data

Datasheet [Click Here To Download]

User's Manual [Click Here To Download